Note: MEGA Live TargetLock wiring diagram included below.
The MEGA Live TargetLock uses the same PC 13 power cable as the MEGA Live Imaging transducer. This means if you had the MEGA Live Imaging transducer installed prior to adding the MEGA Live TargetLock, you will not have to run the additional PC 13 power cable included with your MEGA Live TargetLock Adapter Kit.
The pre-existing MEGA Live power cable provides power to the MEGA Live TargetLock control box. The MEGA Live Imaging transducer will then get power from the MEGA Live TargetLock control box from a different cable (shown below) connecting the two.
See the MEGA Live TargetLock wiring diagram below and perform the following:
- The in-line fuse must be changed from the 2 Amp recommended for the MEGA Live Imaging transducer to a 5 Amp recommended for the MEGA Live TargetLock.
- The MEGA Live Imaging transducer will need to be disconnected from the PC 13 power cable and connected to the appropriate connection point on the MEGA Live TargetLock control box.
- The PC 13 power cable will now connect to the power connector on the MEGA Live TargetLock control box.