This article provides fuse size requirements, power cable extension wire gauge recommendations, and typical current draw specifications for Humminbird, Minn Kota, and related accessories.
JUMP TO:
Humminbird Units and Accessories
Please refer to the following chart for fuse size, power cable extension requirements and the current draw for our Fish Finders and powered accessories.
- In-line fuses are preferred to be glass "Slow Blow" or the MDL equivalent.
- Blade style fuses are also acceptable.
- Wire gauge for power cable extension is listed according to length desired.
- Current Draw on a low battery will be higher than listed.
- Current Draw while on a charger and when the engine is running could be less than listed.
| Humminbird Control Head/ Powered Accessory | Fuse Size Required (Slow Blow/MDL) | Wire Gauge Required for Power Cable Extension | Steady State Current Draw | ||
APEX 19 CHARTPLOTTER |
7.5A |
1-6ft: 12 AWG |
6-12ft: 12 AWG |
12-24ft: 10 AWG |
4.4A |
APEX 16 CHARTPLOTTER |
7.5A |
1-6ft: 12 AWG |
6-12ft: 12 AWG |
12-24ft: 10 AWG |
4.3A |
APEX 13 CHARTPLOTTER |
5A |
1-6ft: 12 AWG |
6-12ft: 12 AWG |
12-24ft: 10 AWG |
3.1A |
XPLORE 12 |
5A |
1-6ft: 12 AWG |
6-12ft: 12 AWG |
12-24ft: 10 AWG |
2.4A |
XPLORE 10 |
5A |
1-6ft: 12 AWG |
6-12ft: 12 AWG |
12-24ft: 10 AWG |
2.2A |
XPLORE 9 |
5A |
1-6ft: 12 AWG |
6-12ft: 12 AWG |
12-24ft: 10 AWG |
2.2A |
SOLIX 15 SERIES |
7.5A |
1-6ft: 12 AWG |
6-12ft: 12 AWG |
12-24ft: 10 AWG |
2.8A |
SOLIX 12 SERIES |
5A |
1-6ft: 12 AWG |
6-12ft: 12 AWG |
12-24ft: 10 AWG |
2.7A |
SOLIX 10 SERIES |
5A |
1-6ft: 12 AWG |
6-12ft: 12 AWG |
12-24ft: 10 AWG |
2.5A |
HDR 650 |
1A |
1-24ft: 18 AWG |
60mA |
||
HELIX 15 SERIES |
7.5A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
4.1A |
HELIX 12 SERIES |
5A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
3.2A |
HELIX 10 SERIES |
5A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
2.7A |
HELIX 9 SERIES |
5A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
1.9A (G4N) 2.4A (G3N and older) |
HELIX 8 SERIES |
5A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
2.4A |
HELIX 7 SERIES |
3A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
800mA |
HELIX 5 SERIES |
3A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
615mA |
ONIX 10 SERIES |
5A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
2.5A |
ONIX 8 SERIES |
5A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
2.5A |
PIRANHAMAX SERIES |
1A |
1-24ft: 18 AWG |
180mA |
||
1100 SERIES |
3A |
1-24ft: 18 AWG |
1.4A |
||
900 SERIES |
3A |
1-24ft: 18 AWG |
1.1A |
||
800 SERIES |
3A |
1-24ft: 18 AWG |
1A |
||
700 SERIES |
3A |
1-24ft: 18 AWG |
650mA |
||
600 SERIES |
3A |
1-24ft: 18 AWG |
500mA |
||
500 SERIES |
3A |
1-24ft: 18 AWG |
550mA |
||
400 SERIES |
1A |
1-24ft: 18 AWG |
200mA |
||
300 SERIES |
1A |
1-24ft: 18 AWG |
406mA |
||
200 SERIES |
1A |
1-24ft: 18 AWG |
200mA |
||
100 SERIES |
1A |
1-24ft: 18 AWG |
200mA |
||
MATRIX SERIES |
3A |
1-24ft: 18 AWG |
550mA |
||
ICE 55 FLASHER |
N/A |
N/A |
250mA |
||
ICE 45 FLASHER |
N/A |
N/A |
250mA |
||
ICE 35 FLASHER |
N/A |
N/A |
210mA |
||
MEGA 360 TRANSDUCER |
1A |
1-24ft: 18 AWG |
500mA |
||
AS 360 TM |
1A |
1-24ft: 18 AWG |
500mA |
||
AS 360 SSI |
8A |
1-24ft: 18 AWG |
360mA (Operating) 4A (Deploy/Retract) |
||
MEGA LIVE (1st Generation) |
2A |
1-24ft: 12 AWG |
930mA |
||
MEGA Live 2 |
2A |
1-24ft: 12 AWG |
1.15A |
||
MEGA LIVE TARGETLOCK |
5A |
1-24ft: 12 AWG |
1.2A |
||
CHIRP RADAR |
5A |
1-24ft: 8 AWG |
Transmit: 1.5A Standby: 600mA |
||
AS ETH 5PXG |
3A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
165mA |
AS ETH 5PGL |
1A |
1-6ft: 18 AWG |
6-12ft: 14 AWG |
12-24ft: 12 AWG |
200mA |
NMEA 2K GPS Heading Sensor |
1A |
1-24ft: SAE 18 AWG |
65mA |
||
HB NMEA 2000 POWER T M |
5A |
1-24ft: 12 AWG |
Up to 4A NMEA Backbone |
||
Note: Some boats have 24 or 36 Volt electric systems, but the control head MUST be connected to a 12 VDC power supply.
Minn Kota Motors, Shallow Water Anchors, and Accessories
CONDUCTOR GAUGE AND CIRCUIT BREAKER SIZING TABLE
This conductor and circuit breaker sizing table are only valid for the following assumptions:
- No more than 2 conductors are bundled together inside of a sheath or conduit outside of engine spaces.
- Each conductor has 105° C temp-rated insulation.
- No more than 3% voltage drop allowed at full motor power based on published product power requirements
*The 30lb thrust motor has been optimized to perform as a portable trolling motor. We therefore do not recommend altering the wire length as it can adversely affect its performance.
Motor Thrust/Model |
Max Amp Draw |
Circuit Breaker |
Wire Extension Length |
||||
5 FT |
10 FT |
15 FT |
20FT |
25FT |
|||
QUEST 24V |
60 Amps |
60 Amp @ 36 VDC |
6 AWG |
6 AWG |
4 AWG |
4 AWG |
2 AWG |
QUEST 36V |
60 Amps |
60 Amp @ 36 VDC |
6 AWG |
6 AWG |
6 AWG |
6 AWG |
4 AWG |
112 lb. |
52 Amps |
60 Amp @ 36 VDC |
8 AWG |
8 AWG |
8 AWG |
6 AWG |
4 AWG |
101 lb. |
46 Amps |
50 Amp @ 36 VDC |
8 AWG |
8 AWG |
8 AWG |
8 AWG |
8 AWG |
80 lb. |
56 Amps |
60 Amp @ 24 VDC |
8 AWG |
6 AWG |
6 AWG |
4 AWG |
2 AWG |
70 lb. |
42 Amps |
50 Amp @ 24 VDC |
8 AWG |
8 AWG |
6 AWG |
6 AWG |
4 AWG |
50 lb., 55 lb. |
50 Amps |
60 Amp @ 12 VDC |
8 AWG |
4 AWG |
2 AWG |
2 AWG |
1 AWG |
40 lb., 45 lb. |
42 Amps |
50 Amp @ 12 VDC |
8 AWG |
6 AWG |
4 AWG |
2 AWG |
2 AWG |
30 lb. * |
30 Amps |
30 Amp @ 12 VDC |
*Do not Extend |
*Do not Extend |
*Do not Extend |
*Do not Extend |
*Do not Extend |
Raptor Shallow Water Anchor |
70 Amps |
50 Amp @ 12 VDC |
10 AWG |
8 AWG |
6 AWG |
4 AWG |
4 AWG |
Talon Shallow Water Anchor |
30 Amps |
50 Amp @ 12 VDC |
8 AWG |
6 AWG |
4 AWG |
4 AWG |
2 AWG |
DeckHand 40 |
30 Amps |
30 Amp @ VDC |
8 AWG |
6 AWG |
4 AWG |
4 AWG |
2 AWG |
Engine Mount 101 |
50 Amps |
50 Amp @ 36 VDC |
8 AWG |
8 AWG |
8 AWG |
6 AWG |
6 AWG |
Engine Mount 160 |
116 Amps |
6 AWG |
4 AWG |
2 AWG |
1 AWG |
1/0 AWG |
|
E-Drive |
40 Amps |
50 Amp @ 48 VDC |
8 AWG |
8 AWG |
8 AWG |
8 AWG |
8 AWG |
NOTICE: Wire Extension Length refers to the distance from the batteries to the trolling motor leads. Consult website for available thrust options. Maximum Amp Draw values only occur intermittently during select conditions and should not be used as continuous amp load ratings.
Reference United States Code of Federal Regulations: 33 CFR 183 – Boats and Associated Equipment ABYC E-11: AC and DC Electrical Systems on Boats